mmc: sdhci: cast unsigned int to unsigned long long to avoid unexpeted error

Potentially overflowing expression 1000000 * data->timeout_clks with
type unsigned int is evaluated using 32-bit arithmetic, and then used
in a context that expects an expression of type unsigned long long.

To avoid overflow, cast 1000000U to type unsigned long long.
Special thanks to Coverity.

Fixes: 7f05538af7 ("mmc: sdhci: fix data timeout (part 2)")
Signed-off-by: Haibo Chen <[email protected]>
Cc: [email protected] # v3.15+
Acked-by: Adrian Hunter <[email protected]>
Signed-off-by: Ulf Hansson <[email protected]>
This commit is contained in:
Haibo Chen 2016-10-17 10:18:37 +02:00 • committed by Ulf Hansson
commit 02265cd603

View file

@ -687,7 +687,7 @@ static u8 sdhci_calc_timeout(struct sdhci_host *host, struct mmc_command *cmd)
* host->clock is in Hz. target_timeout is in us.
* Hence, us = 1000000 * cycles / Hz. Round up.
*/
val = 1000000 * data->timeout_clks;
val = 1000000ULL * data->timeout_clks;
if (do_div(val, host->clock))
target_timeout++;
target_timeout += val;