dts: vt8500: Fix errors in SDHC node for WM8505

According to datasheet, the registers space of SDHC controller is 1Kb,
not '0x1000', the correct value should be '0x400'. Bracket interrupt
numbers individually per recommendations.

Signed-off-by: Roman Volkov <[email protected]>
Signed-off-by: Arnd Bergmann <[email protected]>
This commit is contained in:
Roman Volkov 2016-01-01 16:38:12 +03:00 • committed by Arnd Bergmann
commit 03b9ee45bc

View file

@ -281,8 +281,8 @@
sdhc@d800a000 {
compatible = "wm,wm8505-sdhc";
reg = <0xd800a000 0x1000>;
interrupts = <20 21>;
reg = <0xd800a000 0x400>;
interrupts = <20>, <21>;
clocks = <&clksdhc>;
bus-width = <4>;
};