clk: move the U300 fixed and fixed-factor to DT

This converts the fixed and fixed-factor clocks in the U300
platform to register themselves from the device tree.

Acked-by: Mike Turquette <[email protected]>
Signed-off-by: Linus Walleij <[email protected]>
This commit is contained in:
Linus Walleij 2013-05-23 11:09:57 +02:00
commit 14c2607144
2 changed files with 57 additions and 20 deletions

View file

@ -11,6 +11,7 @@
#include <linux/io.h>
#include <linux/clk-provider.h>
#include <linux/spinlock.h>
#include <linux/of.h>
/* APP side SYSCON registers */
/* CLK Control Register 16bit (R/W) */
@ -931,6 +932,17 @@ mclk_clk_register(struct device *dev, const char *name,
return clk;
}
static const __initconst struct of_device_id u300_clk_match[] = {
{
.compatible = "fixed-clock",
.data = of_fixed_clk_setup,
},
{
.compatible = "fixed-factor-clock",
.data = of_fixed_factor_clk_setup,
},
};
void __init u300_clk_init(void __iomem *base)
{
u16 val;
@ -951,26 +963,7 @@ void __init u300_clk_init(void __iomem *base)
val |= U300_SYSCON_PMCR_PWR_MGNT_ENABLE;
writew(val, syscon_vbase + U300_SYSCON_PMCR);
/* These are always available (RTC and PLL13) */
clk = clk_register_fixed_rate(NULL, "app_32_clk", NULL,
CLK_IS_ROOT, 32768);
/* The watchdog sits directly on the 32 kHz clock */
clk_register_clkdev(clk, NULL, "coh901327_wdog");
clk = clk_register_fixed_rate(NULL, "pll13", NULL,
CLK_IS_ROOT, 13000000);
/* These derive from PLL208 */
clk = clk_register_fixed_rate(NULL, "pll208", NULL,
CLK_IS_ROOT, 208000000);
clk = clk_register_fixed_factor(NULL, "app_208_clk", "pll208",
0, 1, 1);
clk = clk_register_fixed_factor(NULL, "app_104_clk", "pll208",
0, 1, 2);
clk = clk_register_fixed_factor(NULL, "app_52_clk", "pll208",
0, 1, 4);
/* The 52 MHz is divided down to 26 MHz */
clk = clk_register_fixed_factor(NULL, "app_26_clk", "app_52_clk",
0, 1, 2);
of_clk_init(u300_clk_match);
/* Directly on the AMBA interconnect */
clk = syscon_clk_register(NULL, "cpu_clk", "app_208_clk", 0, true,