mirror of
https://github.com/BobTheBlinker/android_kernel_motorola_sm6375.git
synced 2026-10-30 11:41:38 -04:00
rtc: sh: Fix invalid alarm warning for non-enabled alarm
When no alarm has been programmed on RSK-RZA1, an error message is
printed during boot:
rtc rtc0: invalid alarm value: 2019-03-14T255:255:255
sh_rtc_read_alarm_value() returns 0xff when querying a hardware alarm
field that is not enabled. __rtc_read_alarm() validates the received
alarm values, and fills in missing fields when needed.
While 0xff is handled fine for the year, month, and day fields, and
corrected as considered being out-of-range, this is not the case for the
hour, minute, and second fields, where -1 is expected for missing
fields.
Fix this by returning -1 instead, as this value is handled fine for all
fields.
Signed-off-by: Geert Uytterhoeven <[email protected]>
Signed-off-by: Alexandre Belloni <[email protected]>
This commit is contained in:
parent
d6752e185c
commit
15d82d2249
1 changed files with 1 additions and 1 deletions
|
|
@ -374,7 +374,7 @@ static int sh_rtc_set_time(struct device *dev, struct rtc_time *tm)
|
|||
static inline int sh_rtc_read_alarm_value(struct sh_rtc *rtc, int reg_off)
|
||||
{
|
||||
unsigned int byte;
|
||||
int value = 0xff; /* return 0xff for ignored values */
|
||||
int value = -1; /* return -1 for ignored values */
|
||||
|
||||
byte = readb(rtc->regbase + reg_off);
|
||||
if (byte & AR_ENB) {
|
||||
|
|
|
|||
Loading…
Reference in a new issue