bnx2x: Handling PHY FW load failure

If the default PHY version (0x4321) is read - the PHY FW load failed

Signed-off-by: Yaniv Rosner <[email protected]>
Signed-off-by: Eilon Greenstein <[email protected]>
Signed-off-by: David S. Miller <[email protected]>
This commit is contained in:
Eilon Greenstein 2009-01-14 06:44:24 +00:00 • committed by David S. Miller
commit 16b311cc29

View file

@ -4404,10 +4404,11 @@ static u8 bnx2x_8073_common_init_phy(struct bnx2x *bp, u32 shmem_base)
ext_phy_addr[port],
MDIO_PMA_DEVAD,
MDIO_PMA_REG_ROM_VER1, &fw_ver1);
if (fw_ver1 == 0) {
if (fw_ver1 == 0 || fw_ver1 == 0x4321) {
DP(NETIF_MSG_LINK,
"bnx2x_8073_common_init_phy port %x "
"fw Download failed\n", port);
"bnx2x_8073_common_init_phy port %x:"
"Download failed. fw version = 0x%x\n",
port, fw_ver1);
return -EINVAL;
}