ab8500-fg: Use correct battery charge full design

If battery is not identified while fg probe, mah_max_design gets
initialized with unknown battery's charge full design. Reinitialize
mah_max_design if battery is identified after fg probe.

Signed-off-by: Rajkumar Kasirajan <[email protected]>
Signed-off-by: Lee Jones <[email protected]>
Reviewed-by: Vijaya Kumar K-1 <[email protected]>
Reviewed-by: Marcus COOPER <[email protected]>
Reviewed-by: Olivier CLERGEAUD <[email protected]>
Reviewed-by: Arun MURTHY <[email protected]>
Reviewed-by: Rabin VINCENT <[email protected]>
Tested-by: Rupesh KUMAR <[email protected]>
Tested-by: Jonas ABERG <[email protected]>
This commit is contained in:
Rajkumar Kasirajan 2012-05-30 14:54:28 +05:30 • committed by Lee Jones
commit 1a793a1089

View file

@ -2250,7 +2250,8 @@ static int ab8500_fg_get_ext_psy_data(struct device *dev, void *data)
case POWER_SUPPLY_PROP_TECHNOLOGY:
switch (ext->type) {
case POWER_SUPPLY_TYPE_BATTERY:
if (!di->flags.batt_id_received) {
if (!di->flags.batt_id_received &&
di->bm->batt_id != BATTERY_UNKNOWN) {
const struct abx500_battery_type *b;
b = &(di->bm->bat_type[di->bm->batt_id]);