ipmi: Make IPMI panic strings always available

They were set by config items, but people complained that they were
never turned on.  So have them always available and enabled by a
module parameter.

Signed-off-by: Corey Minyard <[email protected]>
This commit is contained in:
Corey Minyard 2017-08-18 17:32:03 -05:00
commit 1c9f98d1bf
3 changed files with 98 additions and 24 deletions

View file

@ -81,7 +81,9 @@ If you want the driver to put an event into the event log on a panic,
enable the 'Generate a panic event to all BMCs on a panic' option. If
you want the whole panic string put into the event log using OEM
events, enable the 'Generate OEM events containing the panic string'
option.
option. You can also enable these dynamically by setting the module
parameter named "panic_op" in the ipmi_msghandler module to "event"
or "string". Setting that parameter to "none" disables this function.
Basic Design
------------