qcacld-3.0: Increase default value of Probe after HB timer to 70msecs

If Probe resp is received just after the Probe after
HB timer expires then it results in disconnection.

Fix is to increase the probe after hb timer default
value to 70msecs.

Change-Id: I0d4ac3e567def348c6b03b41c54579f332099de8
CRs-Fixed: 2111579
This commit is contained in:
Yeshwanth Sriram Guntuka 2017-10-06 14:28:19 +05:30 • committed by snandini
commit 32cc7e8136

View file

@ -656,7 +656,7 @@ enum {
#define WNI_CFG_PROBE_AFTER_HB_FAIL_TIMEOUT_STAMIN 10
#define WNI_CFG_PROBE_AFTER_HB_FAIL_TIMEOUT_STAMAX 10000
#define WNI_CFG_PROBE_AFTER_HB_FAIL_TIMEOUT_STADEF 40
#define WNI_CFG_PROBE_AFTER_HB_FAIL_TIMEOUT_STADEF 70
#define WNI_CFG_11D_ENABLED_STAMIN 0
#define WNI_CFG_11D_ENABLED_STAMAX 1