mirror of
https://github.com/BobTheBlinker/android_kernel_motorola_sm6375.git
synced 2026-10-28 10:41:38 -04:00
charger-manager: Set current limit of regulator for over current protection
This patch support the protection of host device from over current. The Charger-manager set proper current limit of charger(regulator) for charging according to type of charger cable when external connector is attached. Signed-off-by: Chanwoo Choi <[email protected]> Signed-off-by: Myungjoo Ham <[email protected]> Signed-off-by: Kyungmin Park <[email protected]> Signed-off-by: Anton Vorontsov <[email protected]>
This commit is contained in:
parent
bee737bccb
commit
45cd4fb28b
2 changed files with 23 additions and 0 deletions
|
|
@ -1001,6 +1001,21 @@ static void charger_extcon_work(struct work_struct *work)
|
|||
{
|
||||
struct charger_cable *cable =
|
||||
container_of(work, struct charger_cable, wq);
|
||||
int ret;
|
||||
|
||||
if (cable->attached && cable->min_uA != 0 && cable->max_uA != 0) {
|
||||
ret = regulator_set_current_limit(cable->charger->consumer,
|
||||
cable->min_uA, cable->max_uA);
|
||||
if (ret < 0) {
|
||||
pr_err("Cannot set current limit of %s (%s)\n",
|
||||
cable->charger->regulator_name, cable->name);
|
||||
return;
|
||||
}
|
||||
|
||||
pr_info("Set current limit of %s : %duA ~ %duA\n",
|
||||
cable->charger->regulator_name,
|
||||
cable->min_uA, cable->max_uA);
|
||||
}
|
||||
|
||||
try_charger_enable(cable->cm, cable->attached);
|
||||
}
|
||||
|
|
|
|||
Loading…