ITERM80 mA

Set TI-FGes termination current to a lower level to prevent early
charge termination. The higher 200mA level caused lower capacity
Main batt to cycle continuously between chrg and dischrg while
Higher Cap Flip battery catches up.

NO_PROP_NEEDED: TI-FG is specific to SMITH product only

Change-Id: Ifa0504713ab420bb324dd20a73f1868146c9611c
Signed-off-by: Bernie Moreno-BERNIEM <berniem@motorola.com>
Reviewed-on: https://gerrit.mot.com/1672957
SLTApproved: Slta Waiver
SME-Granted: SME Approvals Granted
Tested-by: Jira Key
Reviewed-by: Ling Jin <lingjin@motorola.com>
Submit-Approved: Jira Key
This commit is contained in:
Bernie Moreno-BERNIEM 2020-07-09 20:13:10 -05:00 • committed by Bernie Moreno
commit 4804c2ac9a

View file

@ -2215,7 +2215,7 @@ static void debug_fg_dump_registers(struct bq_fg_chip *bq)
}
}
#define ITERM 200
#define ITERM 80
static void fg_check_soc(struct bq_fg_chip *bq)
{
int batt_status = 0;