thermal: of: Enable thermal_zoneX when sensor is correctly added

Up till now the thermal_zone mode was by default "disabled". With this
patch the default behavior was changed to "enable".

One can read the mode at:
/sys/class/thermal/thermal_zone0/mode

Tested-by: Javi Merino <[email protected]>
Reported-by: Abhilash Kesavan <[email protected]>
Signed-off-by: Lukasz Majewski <[email protected]>
Signed-off-by: Eduardo Valentin <[email protected]>
This commit is contained in:
Lukasz Majewski 2015-01-19 12:44:04 +01:00 • committed by Eduardo Valentin
commit 528012c1f4

View file

@ -497,6 +497,9 @@ thermal_zone_of_sensor_register(struct device *dev, int sensor_id, void *data,
if (sensor_specs.np == sensor_np && id == sensor_id) {
tzd = thermal_zone_of_add_sensor(child, sensor_np,
data, ops);
if (!IS_ERR(tzd))
tzd->ops->set_mode(tzd, THERMAL_DEVICE_ENABLED);
of_node_put(sensor_specs.np);
of_node_put(child);
goto exit;