:charger:The battery level is not change during charging.
WHY:The value of batt_curr is negated, resulting in the wrong state of batt_status. HOW:Delete the negation operation when assigning a value to batt_curr. Change-Id: I66a23033f40e3583893613fad44b11bd796a2824 Reviewed-on: https://gerrit.mot.com/2703113 SME-Granted: SME Approvals Granted SLTApproved: Slta Waiver Tested-by: Jira Key Reviewed-by: Wei Xu <xuwei9@lenovo.com> Reviewed-by: Xiangpo Zhao <zhaoxp3@motorola.com> Submit-Approved: Jira Key
This commit is contained in:
parent
1b85a5a6f7
commit
608b22acd0
1 changed files with 1 additions and 1 deletions
|
|
@ -410,7 +410,7 @@ static int cw_get_ui_full(struct cw_battery *cw_bat, int *ui_full) {
|
|||
static void cw_get_batt_status(struct cw_battery *cw_bat)
|
||||
{
|
||||
long batt_curr = 0;
|
||||
batt_curr = cw_bat->cw_current * CW_CUR_UNIT * (-1);
|
||||
batt_curr = cw_bat->cw_current * CW_CUR_UNIT;
|
||||
batt_curr *= cw_bat->ibat_polority;
|
||||
|
||||
if (cw_bat->voltage <= 0 || cw_bat->temp <= CW_BPD_TEMP)
|
||||
|
|
|
|||