dmaengine/amba-pl08x : reset phychan_hold on terminate all

When a client calls pl08x_control with DMA_TERMINATE_ALL, it is correct
to terminate and release the phy channel currently in use (if one is in use),
but the phychan_hold counter must also be reset (otherwise it could get
trapped in an unbalanced state).

Signed-off-by: Davide Ciminaghi <[email protected]>
Reviewed-by: Viresh Kumar <[email protected]>
Acked-by: Linus Walleij <[email protected]>
Signed-off-by: Vinod Koul <[email protected]>
This commit is contained in:
Davide Ciminaghi 2012-04-19 12:20:24 +02:00 • committed by Vinod Koul
commit 88c08a3fba

View file

@ -1429,6 +1429,7 @@ static int pl08x_control(struct dma_chan *chan, enum dma_ctrl_cmd cmd,
* signal
*/
release_phy_channel(plchan);
plchan->phychan_hold = 0;
}
/* Dequeue jobs and free LLIs */
if (plchan->at) {