hwmon: (menf21bmc) Introduce MEN14F021P00 BMC HWMON driver
Added driver to support the 14F021P00 BMC Hardware Monitoring. The BMC is a Board Management Controller including monitoring of the board voltages. Signed-off-by: Andreas Werner <[email protected]> Reviewed-by: Guenter Roeck <[email protected]> Signed-off-by: Lee Jones <[email protected]>
This commit is contained in:
parent
38433639af
commit
964356938f
4 changed files with 291 additions and 0 deletions
50
Documentation/hwmon/menf21bmc
Normal file
50
Documentation/hwmon/menf21bmc
Normal file
|
|
@ -0,0 +1,50 @@
|
|||
Kernel driver menf21bmc_hwmon
|
||||
=============================
|
||||
|
||||
Supported chips:
|
||||
* MEN 14F021P00
|
||||
Prefix: 'menf21bmc_hwmon'
|
||||
Adresses scanned: -
|
||||
|
||||
Author: Andreas Werner <[email protected]>
|
||||
|
||||
Description
|
||||
-----------
|
||||
|
||||
The menf21bmc is a Board Management Controller (BMC) which provides an I2C
|
||||
interface to the host to access the features implemented in the BMC.
|
||||
|
||||
This driver gives access to the voltage monitoring feature of the main
|
||||
voltages of the board.
|
||||
The voltage sensors are connected to the ADC inputs of the BMC which is
|
||||
a PIC16F917 Mikrocontroller.
|
||||
|
||||
Usage Notes
|
||||
-----------
|
||||
|
||||
This driver is part of the MFD driver named "menf21bmc" and does
|
||||
not auto-detect devices.
|
||||
You will have to instantiate the MFD driver explicitly.
|
||||
Please see Documentation/i2c/instantiating-devices for
|
||||
details.
|
||||
|
||||
Sysfs entries
|
||||
-------------
|
||||
|
||||
The following attributes are supported. All attributes are read only
|
||||
The Limits are read once by the driver.
|
||||
|
||||
in0_input +3.3V input voltage
|
||||
in1_input +5.0V input voltage
|
||||
in2_input +12.0V input voltage
|
||||
in3_input +5V Standby input voltage
|
||||
in4_input VBAT (on board battery)
|
||||
|
||||
in[0-4]_min Minimum voltage limit
|
||||
in[0-4]_max Maximum voltage limit
|
||||
|
||||
in0_label "MON_3_3V"
|
||||
in1_label "MON_5V"
|
||||
in2_label "MON_12V"
|
||||
in3_label "5V_STANDBY"
|
||||
in4_label "VBAT"
|
||||