ARM: dts: qcom: Enable thermal zones and cooling devices for sa8195
Enable TSENS different thermal zones like userspace thermal zones, CPU isolation thermal zones, gpu max thermal zones, CDSP, NPU thermal zones and pmic alarm thermal zones etc. and different cooling devices for sa8195. Change-Id: I9cabba6e2d11875c869480e11501a24ff2eb7327
This commit is contained in:
parent
ed738acd32
commit
9c6bd0d9be
4 changed files with 1269 additions and 6 deletions
|
|
@ -59,6 +59,13 @@
|
|||
/delete-node/ refgen;
|
||||
};
|
||||
|
||||
&lmh_dcvs1 {
|
||||
isens_vref_0p8-supply = <&pm8195_3_l5>;
|
||||
isens-vref-0p8-settings = <880000 880000 20000>;
|
||||
isens_vref_1p8-supply = <&pm8195_1_l12>;
|
||||
isens-vref-1p8-settings = <1800000 1800000 20000>;
|
||||
};
|
||||
|
||||
&camcc {
|
||||
vdd_mx-supply = <&VDD_MX_LEVEL>;
|
||||
vdd_mm-supply = <&VDD_MMCX_LEVEL>;
|
||||
|
|
@ -97,6 +104,59 @@
|
|||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
/*
|
||||
* trip0 cooling map is dummy node to enable
|
||||
* passive polling on trip0 violation.
|
||||
*/
|
||||
trip0_cpu0 {
|
||||
trip = <&pm8195_1_trip0>;
|
||||
cooling-device = <&CPU0 0 0>;
|
||||
};
|
||||
|
||||
trip1_cpu0 {
|
||||
trip = <&pm8195_1_trip1>;
|
||||
cooling-device =
|
||||
<&CPU0 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
|
||||
trip1_cpu1 {
|
||||
trip = <&pm8195_1_trip1>;
|
||||
cooling-device = <&cpu1_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu2 {
|
||||
trip = <&pm8195_1_trip1>;
|
||||
cooling-device = <&cpu2_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu3 {
|
||||
trip = <&pm8195_1_trip1>;
|
||||
cooling-device = <&cpu3_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu4 {
|
||||
trip = <&pm8195_1_trip1>;
|
||||
cooling-device = <&cpu4_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu5 {
|
||||
trip = <&pm8195_1_trip1>;
|
||||
cooling-device = <&cpu5_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu6 {
|
||||
trip = <&pm8195_1_trip1>;
|
||||
cooling-device = <&cpu6_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu7 {
|
||||
trip = <&pm8195_1_trip1>;
|
||||
cooling-device = <&cpu7_isolate 1 1>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
pm8195_2_temp_alarm: pm8195_2_tz {
|
||||
|
|
@ -124,6 +184,59 @@
|
|||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
/*
|
||||
* trip0 cooling map is dummy node to enable
|
||||
* passive polling on trip0 violation.
|
||||
*/
|
||||
trip0_cpu0 {
|
||||
trip = <&pm8195_2_trip0>;
|
||||
cooling-device = <&CPU0 0 0>;
|
||||
};
|
||||
|
||||
trip1_cpu0 {
|
||||
trip = <&pm8195_2_trip1>;
|
||||
cooling-device =
|
||||
<&CPU0 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
|
||||
trip1_cpu1 {
|
||||
trip = <&pm8195_2_trip1>;
|
||||
cooling-device = <&cpu1_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu2 {
|
||||
trip = <&pm8195_2_trip1>;
|
||||
cooling-device = <&cpu2_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu3 {
|
||||
trip = <&pm8195_2_trip1>;
|
||||
cooling-device = <&cpu3_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu4 {
|
||||
trip = <&pm8195_2_trip1>;
|
||||
cooling-device = <&cpu4_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu5 {
|
||||
trip = <&pm8195_2_trip1>;
|
||||
cooling-device = <&cpu5_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu6 {
|
||||
trip = <&pm8195_2_trip1>;
|
||||
cooling-device = <&cpu6_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu7 {
|
||||
trip = <&pm8195_2_trip1>;
|
||||
cooling-device = <&cpu7_isolate 1 1>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
pm8195_3_temp_alarm: pm8195_3_tz {
|
||||
|
|
@ -151,5 +264,58 @@
|
|||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
/*
|
||||
* trip0 cooling map is dummy node to enable
|
||||
* passive polling on trip0 violation.
|
||||
*/
|
||||
trip0_cpu0 {
|
||||
trip = <&pm8195_3_trip0>;
|
||||
cooling-device = <&CPU0 0 0>;
|
||||
};
|
||||
|
||||
trip1_cpu0 {
|
||||
trip = <&pm8195_3_trip1>;
|
||||
cooling-device =
|
||||
<&CPU0 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
|
||||
trip1_cpu1 {
|
||||
trip = <&pm8195_3_trip1>;
|
||||
cooling-device = <&cpu1_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu2 {
|
||||
trip = <&pm8195_3_trip1>;
|
||||
cooling-device = <&cpu2_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu3 {
|
||||
trip = <&pm8195_3_trip1>;
|
||||
cooling-device = <&cpu3_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu4 {
|
||||
trip = <&pm8195_3_trip1>;
|
||||
cooling-device = <&cpu4_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu5 {
|
||||
trip = <&pm8195_3_trip1>;
|
||||
cooling-device = <&cpu5_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu6 {
|
||||
trip = <&pm8195_3_trip1>;
|
||||
cooling-device = <&cpu6_isolate 1 1>;
|
||||
};
|
||||
|
||||
trip1_cpu7 {
|
||||
trip = <&pm8195_3_trip1>;
|
||||
cooling-device = <&cpu7_isolate 1 1>;
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
||||
|
|
|
|||
1092
qcom/sa8195-thermal.dtsi
Normal file
1092
qcom/sa8195-thermal.dtsi
Normal file
File diff suppressed because it is too large
Load diff
|
|
@ -39,6 +39,8 @@
|
|||
|
||||
qcom,gpu-qdss-stm = <0x161c0000 0x40000>; /* base addr, size */
|
||||
|
||||
#cooling-cells = <2>;
|
||||
|
||||
clocks = <&gcc GCC_GPU_CFG_AHB_CLK>,
|
||||
<&gpucc GPU_CC_CXO_CLK>,
|
||||
<&gcc GCC_DDRSS_GPU_AXI_CLK>,
|
||||
|
|
|
|||
|
|
@ -54,6 +54,7 @@
|
|||
cache-size = <0x8000>;
|
||||
next-level-cache = <&L2_0>;
|
||||
qcom,freq-domain = <&cpufreq_hw 0 4>;
|
||||
qcom,lmh-dcvs = <&lmh_dcvs0>;
|
||||
#cooling-cells = <2>;
|
||||
L2_0: l2-cache {
|
||||
compatible = "arm,arch-cache";
|
||||
|
|
@ -79,7 +80,7 @@
|
|||
cache-size = <0x8000>;
|
||||
next-level-cache = <&L2_1>;
|
||||
qcom,freq-domain = <&cpufreq_hw 0 4>;
|
||||
#cooling-cells = <2>;
|
||||
qcom,lmh-dcvs = <&lmh_dcvs0>;
|
||||
L2_1: l2-cache {
|
||||
compatible = "arm,arch-cache";
|
||||
cache-size = <0x20000>;
|
||||
|
|
@ -98,7 +99,7 @@
|
|||
cache-size = <0x8000>;
|
||||
next-level-cache = <&L2_2>;
|
||||
qcom,freq-domain = <&cpufreq_hw 0 4>;
|
||||
#cooling-cells = <2>;
|
||||
qcom,lmh-dcvs = <&lmh_dcvs0>;
|
||||
L2_2: l2-cache {
|
||||
compatible = "arm,arch-cache";
|
||||
cache-size = <0x20000>;
|
||||
|
|
@ -117,7 +118,7 @@
|
|||
cache-size = <0x8000>;
|
||||
next-level-cache = <&L2_3>;
|
||||
qcom,freq-domain = <&cpufreq_hw 0 4>;
|
||||
#cooling-cells = <2>;
|
||||
qcom,lmh-dcvs = <&lmh_dcvs0>;
|
||||
L2_3: l2-cache {
|
||||
compatible = "arm,arch-cache";
|
||||
cache-size = <0x20000>;
|
||||
|
|
@ -136,6 +137,7 @@
|
|||
cache-size = <0x20000>;
|
||||
next-level-cache = <&L2_4>;
|
||||
qcom,freq-domain = <&cpufreq_hw 1 4>;
|
||||
qcom,lmh-dcvs = <&lmh_dcvs1>;
|
||||
#cooling-cells = <2>;
|
||||
L2_4: l2-cache {
|
||||
compatible = "arm,arch-cache";
|
||||
|
|
@ -155,7 +157,7 @@
|
|||
cache-size = <0x20000>;
|
||||
next-level-cache = <&L2_5>;
|
||||
qcom,freq-domain = <&cpufreq_hw 1 4>;
|
||||
#cooling-cells = <2>;
|
||||
qcom,lmh-dcvs = <&lmh_dcvs1>;
|
||||
L2_5: l2-cache {
|
||||
compatible = "arm,arch-cache";
|
||||
cache-size = <0x80000>;
|
||||
|
|
@ -174,7 +176,7 @@
|
|||
cache-size = <0x20000>;
|
||||
next-level-cache = <&L2_6>;
|
||||
qcom,freq-domain = <&cpufreq_hw 1 4>;
|
||||
#cooling-cells = <2>;
|
||||
qcom,lmh-dcvs = <&lmh_dcvs1>;
|
||||
L2_6: l2-cache {
|
||||
compatible = "arm,arch-cache";
|
||||
cache-size = <0x80000>;
|
||||
|
|
@ -193,7 +195,7 @@
|
|||
cache-size = <0x20000>;
|
||||
next-level-cache = <&L2_7>;
|
||||
qcom,freq-domain = <&cpufreq_hw 1 4>;
|
||||
#cooling-cells = <2>;
|
||||
qcom,lmh-dcvs = <&lmh_dcvs1>;
|
||||
L2_7: l2-cache {
|
||||
compatible = "arm,arch-cache";
|
||||
cache-size = <0x80000>;
|
||||
|
|
@ -2317,6 +2319,7 @@
|
|||
#include "sa8195-vidc.dtsi"
|
||||
#include "sa8155-audio.dtsi"
|
||||
#include "sm8150-npu.dtsi"
|
||||
#include "sa8195-thermal.dtsi"
|
||||
|
||||
#include "display/sdmshrike-sde-pll.dtsi"
|
||||
#include "display/sdmshrike-sde.dtsi"
|
||||
|
|
|
|||
Loading…