From a506ab6e4b25f804aa750faae0a35bf709f4cf13 Mon Sep 17 00:00:00 2001 From: mahj8 Date: Thu, 24 Feb 2022 18:05:31 +0800 Subject: [PATCH] arm/dts: change the main charger icl 300ma This platform don't have mmi_battery for 33W, we need change it to battery power supply. change max charger icl to 300ma when charger pump enable. Change-Id: Ibbef411b53a47e305134d75217821c8d58e473df Signed-off-by: mahj8 Reviewed-on: https://gerrit.mot.com/2200417 SME-Granted: SME Approvals Granted SLTApproved: Slta Waiver Tested-by: Jira Key Reviewed-by: Lei Chen Reviewed-by: Huosheng Liao Submit-Approved: Jira Key --- qcom/discrete_charging_rhodep.dtsi | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/qcom/discrete_charging_rhodep.dtsi b/qcom/discrete_charging_rhodep.dtsi index b977b228ca41..d227a30e1d07 100644 --- a/qcom/discrete_charging_rhodep.dtsi +++ b/qcom/discrete_charging_rhodep.dtsi @@ -392,8 +392,8 @@ <1000000>; charger_device_0 { chrg-name = "pmic-sw"; - psy-name = "mmi_battery"; - charging-curr-limited = <500000>; + psy-name = "battery"; + charging-curr-limited = <300000>; }; charger_device_1 { chrg-name = "cp-master";