mirror of
https://github.com/BobTheBlinker/android_kernel_motorola_sm6375.git
synced 2026-10-28 02:32:09 -04:00
Merge git://git.infradead.org/mtd-2.6
* git://git.infradead.org/mtd-2.6: (58 commits)
mtd: jedec_probe: add PSD4256G6V id
mtd: OneNand support for Nomadik 8815 SoC (on NHK8815 board)
mtd: nand: driver for Nomadik 8815 SoC (on NHK8815 board)
m25p80: Add Spansion S25FL129P serial flashes
jffs2: Use SLAB_HWCACHE_ALIGN for jffs2_raw_{dirent,inode} slabs
mtd: sh_flctl: register sh_flctl using platform_driver_probe()
mtd: nand: txx9ndfmc: transfer 512 byte at a time if possible
mtd: nand: fix tmio_nand ecc correction
mtd: nand: add __nand_correct_data helper function
mtd: cfi_cmdset_0002: add 0xFF intolerance for M29W128G
mtd: inftl: fix fold chain block number
mtd: jedec: fix compilation problem with I28F640C3B definition
mtd: nand: fix ECC Correction bug for SMC ordering for NDFC driver
mtd: ofpart: Check availability of reg property instead of name property
driver/Makefile: Initialize "mtd" and "spi" before "net"
mtd: omap: adding DMA mode support in nand prefetch/post-write
mtd: omap: add support for nand prefetch-read and post-write
mtd: add nand support for w90p910 (v2)
mtd: maps: add mtd-ram support to physmap_of
mtd: pxa3xx_nand: add single-bit error corrections reporting
...
This commit is contained in:
commit
a7c367b95a
64 changed files with 2795 additions and 251 deletions
|
|
@ -1,18 +1,19 @@
|
|||
CFI or JEDEC memory-mapped NOR flash
|
||||
CFI or JEDEC memory-mapped NOR flash, MTD-RAM (NVRAM...)
|
||||
|
||||
Flash chips (Memory Technology Devices) are often used for solid state
|
||||
file systems on embedded devices.
|
||||
|
||||
- compatible : should contain the specific model of flash chip(s)
|
||||
used, if known, followed by either "cfi-flash" or "jedec-flash"
|
||||
- reg : Address range(s) of the flash chip(s)
|
||||
- compatible : should contain the specific model of mtd chip(s)
|
||||
used, if known, followed by either "cfi-flash", "jedec-flash"
|
||||
or "mtd-ram".
|
||||
- reg : Address range(s) of the mtd chip(s)
|
||||
It's possible to (optionally) define multiple "reg" tuples so that
|
||||
non-identical NOR chips can be described in one flash node.
|
||||
- bank-width : Width (in bytes) of the flash bank. Equal to the
|
||||
non-identical chips can be described in one node.
|
||||
- bank-width : Width (in bytes) of the bank. Equal to the
|
||||
device width times the number of interleaved chips.
|
||||
- device-width : (optional) Width of a single flash chip. If
|
||||
- device-width : (optional) Width of a single mtd chip. If
|
||||
omitted, assumed to be equal to 'bank-width'.
|
||||
- #address-cells, #size-cells : Must be present if the flash has
|
||||
- #address-cells, #size-cells : Must be present if the device has
|
||||
sub-nodes representing partitions (see below). In this case
|
||||
both #address-cells and #size-cells must be equal to 1.
|
||||
|
||||
|
|
@ -22,24 +23,24 @@ are defined:
|
|||
- vendor-id : Contains the flash chip's vendor id (1 byte).
|
||||
- device-id : Contains the flash chip's device id (1 byte).
|
||||
|
||||
In addition to the information on the flash bank itself, the
|
||||
In addition to the information on the mtd bank itself, the
|
||||
device tree may optionally contain additional information
|
||||
describing partitions of the flash address space. This can be
|
||||
describing partitions of the address space. This can be
|
||||
used on platforms which have strong conventions about which
|
||||
portions of the flash are used for what purposes, but which don't
|
||||
portions of a flash are used for what purposes, but which don't
|
||||
use an on-flash partition table such as RedBoot.
|
||||
|
||||
Each partition is represented as a sub-node of the flash device.
|
||||
Each partition is represented as a sub-node of the mtd device.
|
||||
Each node's name represents the name of the corresponding
|
||||
partition of the flash device.
|
||||
partition of the mtd device.
|
||||
|
||||
Flash partitions
|
||||
- reg : The partition's offset and size within the flash bank.
|
||||
- label : (optional) The label / name for this flash partition.
|
||||
- reg : The partition's offset and size within the mtd bank.
|
||||
- label : (optional) The label / name for this partition.
|
||||
If omitted, the label is taken from the node name (excluding
|
||||
the unit address).
|
||||
- read-only : (optional) This parameter, if present, is a hint to
|
||||
Linux that this flash partition should only be mounted
|
||||
Linux that this partition should only be mounted
|
||||
read-only. This is usually used for flash partitions
|
||||
containing early-boot firmware images or data which should not
|
||||
be clobbered.
|
||||
|
|
@ -78,3 +79,12 @@ Here an example with multiple "reg" tuples:
|
|||
reg = <0 0x04000000>;
|
||||
};
|
||||
};
|
||||
|
||||
An example using SRAM:
|
||||
|
||||
sram@2,0 {
|
||||
compatible = "samsung,k6f1616u6a", "mtd-ram";
|
||||
reg = <2 0 0x00200000>;
|
||||
bank-width = <2>;
|
||||
};
|
||||
|
||||
|
|
|
|||
Loading…
Reference in a new issue