rtc-ds1307: typo fix found by coverity

Fix a typo turned up by a Coverity check:  referring to the wrong register,
which could cause problems with DS1338 RTCs whose oscillators halted.

Signed-off-by: David Brownell <[email protected]>
Signed-off-by: Andrew Morton <[email protected]>
Signed-off-by: Linus Torvalds <[email protected]>
This commit is contained in:
David Brownell 2007-07-26 10:41:00 -07:00 • committed by Linus Torvalds
commit bd16f9ebd0

View file

@ -352,7 +352,7 @@ read_rtc:
/* oscillator fault? clear flag, and warn */
if (ds1307->regs[DS1307_REG_CONTROL] & DS1338_BIT_OSF) {
i2c_smbus_write_byte_data(client, DS1307_REG_CONTROL,
ds1307->regs[DS1337_REG_CONTROL]
ds1307->regs[DS1307_REG_CONTROL]
& ~DS1338_BIT_OSF);
dev_warn(&client->dev, "SET TIME!\n");
goto read_rtc;