Merge branch 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux

Pull thermal management updates from Zhang Rui:

 - Introduce generic ADC thermal driver, based on OF thermal (Laxman
   Dewangan)

 - Introduce new thermal driver for Tango chips (Marc Gonzalez)

 - Rockchip driver support for RK3399, RK3366, and some fixes (Caesar
   Wang, Elaine Zhang and Shawn Lin)

 - Add CPU power cooling model to Mediatek thermal driver (Dawei Chien)

 - Wider usage of dev_thermal_zone_of_sensor_register (Eduardo Valentin)

 - TI thermal driver gained a new maintainer (Keerthy).

 - Enabled powerclamp driver by checking CPU feature and package cstate
   counter instead of CPU whitelist (Jacob Pan)

 - Various fixes on thermal governor, OF thermal, Tegra, and RCAR

* 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: (50 commits)
  thermal: tango: initialize TEMPSI_CFG
  thermal: rockchip: use the usleep_range instead of udelay
  thermal: rockchip: add the notes for better reading
  thermal: rockchip: Support RK3366 SoCs in the thermal driver
  thermal: rockchip: handle the power sequence for tsadc controller
  thermal: rockchip: update the tsadc table for rk3399
  thermal: rockchip: fixes the code_to_temp for tsadc driver
  thermal: rockchip: disable thermal->clk in err case
  thermal: tegra: add Tegra132 specific SOC_THERM driver
  thermal: fix ptr_ret.cocci warnings
  thermal: mediatek: Add cpu dynamic power cooling model.
  thermal: generic-adc: Add ADC based thermal sensor driver
  thermal: generic-adc: Add DT binding for ADC based thermal sensor
  thermal: tegra: fix static checker warning
  thermal: tegra: mark PM functions __maybe_unused
  thermal: add temperature sensor support for tango SoC
  thermal: hisilicon: fix IRQ imbalance enabling
  thermal: hisilicon: support to use any sensor
  thermal: rcar: Remove binding docs for r8a7794
  thermal: tegra: add PM support
  ...
This commit is contained in:
Linus Torvalds 2016-05-26 09:23:43 -07:00
commit bfb764440d
38 changed files with 2414 additions and 763 deletions

View file

@ -26,6 +26,10 @@ Required properties :
of this property. See <dt-bindings/thermal/tegra124-soctherm.h> for a
list of valid values when referring to thermal sensors.
Note:
- the "critical" type trip points will be set to SOC_THERM hardware as the
shut down temperature. Once the temperature of this thermal zone is higher
than it, the system will be shutdown or reset by hardware.
Example :
@ -51,5 +55,13 @@ Example: referring to thermal sensors :
thermal-sensors =
<&soctherm TEGRA124_SOCTHERM_SENSOR_CPU>;
trips {
cpu_shutdown_trip: shutdown-trip {
temperature = <102500>;
hysteresis = <1000>;
type = "critical";
};
};
};
};

View file

@ -11,7 +11,6 @@ Required properties:
- "renesas,thermal-r8a7791" (R-Car M2-W)
- "renesas,thermal-r8a7792" (R-Car V2H)
- "renesas,thermal-r8a7793" (R-Car M2-N)
- "renesas,thermal-r8a7794" (R-Car E2)
- reg : Address range of the thermal registers.
The 1st reg will be recognized as common register
if it has "interrupts".

View file

@ -0,0 +1,17 @@
* Tango Thermal
The SMP8758 SoC includes 3 instances of this temperature sensor
(in the CPU, video decoder, and PCIe controller).
Required properties:
- #thermal-sensor-cells: Should be 0 (see thermal.txt)
- compatible: "sigma,smp8758-thermal"
- reg: Address range of the thermal registers
Example:
cpu_temp: thermal@920100 {
#thermal-sensor-cells = <0>;
compatible = "sigma,smp8758-thermal";
reg = <0x920100 12>;
};

View file

@ -0,0 +1,89 @@
General Purpose Analog To Digital Converter (ADC) based thermal sensor.
On some of platforms, thermal sensor like thermistors are connected to
one of ADC channel and sensor resistance is read via voltage across the
sensor resistor. The voltage read across the sensor is mapped to
temperature using voltage-temperature lookup table.
Required properties:
===================
- compatible: Must be "generic-adc-thermal".
- temperature-lookup-table: Two dimensional array of Integer; lookup table
to map the relation between ADC value and
temperature. When ADC is read, the value is
looked up on the table to get the equivalent
temperature.
The first value of the each row of array is the
temperature in milliCelsius and second value of
the each row of array is the ADC read value.
- #thermal-sensor-cells: Should be 1. See ./thermal.txt for a description
of this property.
Example :
#include <dt-bindings/thermal/thermal.h>
i2c@7000c400 {
ads1015: ads1015@4a {
reg = <0x4a>;
compatible = "ads1015";
sampling-frequency = <3300>;
#io-channel-cells = <1>;
};
};
tboard_thermistor: thermal-sensor {
compatible = "generic-adc-thermal";
#thermal-sensor-cells = <0>;
io-channels = <&ads1015 1>;
io-channel-names = "sensor-channel";
temperature-lookup-table = < (-40000) 2578
(-39000) 2577
(-38000) 2576
(-37000) 2575
(-36000) 2574
(-35000) 2573
(-34000) 2572
(-33000) 2571
(-32000) 2569
(-31000) 2568
(-30000) 2567
::::::::::
118000 254
119000 247
120000 240
121000 233
122000 226
123000 220
124000 214
125000 208>;
};
dummy_cool_dev: dummy-cool-dev {
compatible = "dummy-cooling-dev";
#cooling-cells = <2>; /* min followed by max */
};
thermal-zones {
Tboard {
polling-delay = <15000>; /* milliseconds */
polling-delay-passive = <0>; /* milliseconds */
thermal-sensors = <&tboard_thermistor>;
trips {
therm_est_trip: therm_est_trip {
temperature = <40000>;
type = "active";
hysteresis = <1000>;
};
};
cooling-maps {
map0 {
trip = <&therm_est_trip>;
cooling-device = <&dummy_cool_dev THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
contribution = <100>;
};
};
};
};

View file

@ -69,8 +69,8 @@ temperature) and throttle appropriate devices.
1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
This interface function removes the thermal zone device.
It deletes the corresponding entry form /sys/class/thermal folder and
unbind all the thermal cooling devices it uses.
It deletes the corresponding entry from /sys/class/thermal folder and
unbinds all the thermal cooling devices it uses.
1.1.3 struct thermal_zone_device *thermal_zone_of_sensor_register(
struct device *dev, int sensor_id, void *data,
@ -146,32 +146,32 @@ temperature) and throttle appropriate devices.
This interface function adds a new thermal cooling device (fan/processor/...)
to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
to all the thermal zone devices register at the same time.
to all the thermal zone devices registered at the same time.
name: the cooling device name.
devdata: device private data.
ops: thermal cooling devices call-backs.
.get_max_state: get the Maximum throttle state of the cooling device.
.get_cur_state: get the Current throttle state of the cooling device.
.get_cur_state: get the Currently requested throttle state of the cooling device.
.set_cur_state: set the Current throttle state of the cooling device.
1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
This interface function remove the thermal cooling device.
It deletes the corresponding entry form /sys/class/thermal folder and
unbind itself from all the thermal zone devices using it.
This interface function removes the thermal cooling device.
It deletes the corresponding entry from /sys/class/thermal folder and
unbinds itself from all the thermal zone devices using it.
1.3 interface for binding a thermal zone device with a thermal cooling device
1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
int trip, struct thermal_cooling_device *cdev,
unsigned long upper, unsigned long lower, unsigned int weight);
This interface function bind a thermal cooling device to the certain trip
This interface function binds a thermal cooling device to a particular trip
point of a thermal zone device.
This function is usually called in the thermal zone device .bind callback.
tz: the thermal zone device
cdev: thermal cooling device
trip: indicates which trip point the cooling devices is associated with
in this thermal zone.
trip: indicates which trip point in this thermal zone the cooling device
is associated with.
upper:the Maximum cooling state for this trip point.
THERMAL_NO_LIMIT means no upper limit,
and the cooling device can be in max_state.
@ -184,13 +184,13 @@ temperature) and throttle appropriate devices.
1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
int trip, struct thermal_cooling_device *cdev);
This interface function unbind a thermal cooling device from the certain
This interface function unbinds a thermal cooling device from a particular
trip point of a thermal zone device. This function is usually called in
the thermal zone device .unbind callback.
tz: the thermal zone device
cdev: thermal cooling device
trip: indicates which trip point the cooling devices is associated with
in this thermal zone.
trip: indicates which trip point in this thermal zone the cooling device
is associated with.
1.4 Thermal Zone Parameters
1.4.1 struct thermal_bind_params
@ -210,13 +210,13 @@ temperature) and throttle appropriate devices.
this thermal zone and cdev, for a particular trip point.
If nth bit is set, then the cdev and thermal zone are bound
for trip point n.
.limits: This is an array of cooling state limits. Must have exactly
2 * thermal_zone.number_of_trip_points. It is an array consisting
of tuples <lower-state upper-state> of state limits. Each trip
will be associated with one state limit tuple when binding.
A NULL pointer means <THERMAL_NO_LIMITS THERMAL_NO_LIMITS>
on all trips. These limits are used when binding a cdev to a
trip point.
.binding_limits: This is an array of cooling state limits. Must have
exactly 2 * thermal_zone.number_of_trip_points. It is an
array consisting of tuples <lower-state upper-state> of
state limits. Each trip will be associated with one state
limit tuple when binding. A NULL pointer means
<THERMAL_NO_LIMITS THERMAL_NO_LIMITS> on all trips.
These limits are used when binding a cdev to a trip point.
.match: This call back returns success(0) if the 'tz and cdev' need to
be bound, as per platform data.
1.4.2 struct thermal_zone_params
@ -351,8 +351,8 @@ cdev[0-*]
RO, Optional
cdev[0-*]_trip_point
The trip point with which cdev[0-*] is associated in this thermal
zone; -1 means the cooling device is not associated with any trip
The trip point in this thermal zone which cdev[0-*] is associated
with; -1 means the cooling device is not associated with any trip
point.
RO, Optional