mirror of
https://github.com/BobTheBlinker/android_kernel_motorola_sm6375.git
synced 2026-10-28 18:51:56 -04:00
Pull thinkpad-2.6.24 into release branch
This commit is contained in:
commit
d12dbbfe94
3 changed files with 226 additions and 82 deletions
|
|
@ -1,7 +1,7 @@
|
|||
ThinkPad ACPI Extras Driver
|
||||
|
||||
Version 0.16
|
||||
August 2nd, 2007
|
||||
Version 0.17
|
||||
October 04th, 2007
|
||||
|
||||
Borislav Deianov <[email protected]>
|
||||
Henrique de Moraes Holschuh <[email protected]>
|
||||
|
|
@ -923,19 +923,34 @@ sysfs backlight device "thinkpad_screen"
|
|||
This feature allows software control of the LCD brightness on ThinkPad
|
||||
models which don't have a hardware brightness slider.
|
||||
|
||||
It has some limitations: the LCD backlight cannot be actually turned on or off
|
||||
by this interface, and in many ThinkPad models, the "dim while on battery"
|
||||
functionality will be enabled by the BIOS when this interface is used, and
|
||||
cannot be controlled.
|
||||
It has some limitations: the LCD backlight cannot be actually turned on or
|
||||
off by this interface, and in many ThinkPad models, the "dim while on
|
||||
battery" functionality will be enabled by the BIOS when this interface is
|
||||
used, and cannot be controlled.
|
||||
|
||||
The backlight control has eight levels, ranging from 0 to 7. Some of the
|
||||
levels may not be distinct.
|
||||
On IBM (and some of the earlier Lenovo) ThinkPads, the backlight control
|
||||
has eight brightness levels, ranging from 0 to 7. Some of the levels
|
||||
may not be distinct. Later Lenovo models that implement the ACPI
|
||||
display backlight brightness control methods have 16 levels, ranging
|
||||
from 0 to 15.
|
||||
|
||||
There are two interfaces to the firmware for brightness control, EC and CMOS.
|
||||
To select which one should be used, use the brightness_mode module parameter:
|
||||
brightness_mode=1 selects EC mode, brightness_mode=2 selects CMOS mode,
|
||||
brightness_mode=3 selects both EC and CMOS. The driver tries to autodetect
|
||||
which interface to use.
|
||||
There are two interfaces to the firmware for direct brightness control,
|
||||
EC and CMOS. To select which one should be used, use the
|
||||
brightness_mode module parameter: brightness_mode=1 selects EC mode,
|
||||
brightness_mode=2 selects CMOS mode, brightness_mode=3 selects both EC
|
||||
and CMOS. The driver tries to autodetect which interface to use.
|
||||
|
||||
When display backlight brightness controls are available through the
|
||||
standard ACPI interface, it is best to use it instead of this direct
|
||||
ThinkPad-specific interface. The driver will disable its native
|
||||
backlight brightness control interface if it detects that the standard
|
||||
ACPI interface is available in the ThinkPad.
|
||||
|
||||
The brightness_enable module parameter can be used to control whether
|
||||
the LCD brightness control feature will be enabled when available.
|
||||
brightness_enable=0 forces it to be disabled. brightness_enable=1
|
||||
forces it to be enabled when available, even if the standard ACPI
|
||||
interface is also available.
|
||||
|
||||
Procfs notes:
|
||||
|
||||
|
|
@ -947,11 +962,11 @@ Procfs notes:
|
|||
|
||||
Sysfs notes:
|
||||
|
||||
The interface is implemented through the backlight sysfs class, which is poorly
|
||||
documented at this time.
|
||||
The interface is implemented through the backlight sysfs class, which is
|
||||
poorly documented at this time.
|
||||
|
||||
Locate the thinkpad_screen device under /sys/class/backlight, and inside it
|
||||
there will be the following attributes:
|
||||
Locate the thinkpad_screen device under /sys/class/backlight, and inside
|
||||
it there will be the following attributes:
|
||||
|
||||
max_brightness:
|
||||
Reads the maximum brightness the hardware can be set to.
|
||||
|
|
@ -961,17 +976,19 @@ there will be the following attributes:
|
|||
Reads what brightness the screen is set to at this instant.
|
||||
|
||||
brightness:
|
||||
Writes request the driver to change brightness to the given
|
||||
value. Reads will tell you what brightness the driver is trying
|
||||
to set the display to when "power" is set to zero and the display
|
||||
has not been dimmed by a kernel power management event.
|
||||
Writes request the driver to change brightness to the
|
||||
given value. Reads will tell you what brightness the
|
||||
driver is trying to set the display to when "power" is set
|
||||
to zero and the display has not been dimmed by a kernel
|
||||
power management event.
|
||||
|
||||
power:
|
||||
power management mode, where 0 is "display on", and 1 to 3 will
|
||||
dim the display backlight to brightness level 0 because
|
||||
thinkpad-acpi cannot really turn the backlight off. Kernel
|
||||
power management events can temporarily increase the current
|
||||
power management level, i.e. they can dim the display.
|
||||
power management mode, where 0 is "display on", and 1 to 3
|
||||
will dim the display backlight to brightness level 0
|
||||
because thinkpad-acpi cannot really turn the backlight
|
||||
off. Kernel power management events can temporarily
|
||||
increase the current power management level, i.e. they can
|
||||
dim the display.
|
||||
|
||||
|
||||
Volume control -- /proc/acpi/ibm/volume
|
||||
|
|
|
|||
Loading…