power: supply: charger-manager: Fix typo in condition

Should be discharging_max_duration_ms, not charging_max_duration_ms.

Signed-off-by: Ryosuke Saito <[email protected]>
Signed-off-by: Sebastian Reichel <[email protected]>
This commit is contained in:
Ryosuke Saito 2017-11-21 13:27:12 +09:00 • committed by Sebastian Reichel
commit f46b151ede

View file

@ -578,7 +578,7 @@ static int check_charging_duration(struct charger_manager *cm)
} else if (is_ext_pwr_online(cm) && !cm->charger_enabled) {
duration = curr - cm->charging_end_time;
if (duration > desc->charging_max_duration_ms &&
if (duration > desc->discharging_max_duration_ms &&
is_ext_pwr_online(cm)) {
dev_info(cm->dev, "Discharging duration exceed %ums\n",
desc->discharging_max_duration_ms);