charging: defined default termination current 120ma

As cyprus IP68 SW terminate current is 150ma, so HW
termination current need set below 150ma.

Change-Id: Ib52492992495e03945943b18363ea58f1cf6a49f
Signed-off-by: mahj8 <mahj8@motorola.com>
Reviewed-on: https://gerrit.mot.com/2116841
SLTApproved: Slta Waiver
SME-Granted: SME Approvals Granted
Tested-by: Jira Key
Reviewed-by: Huosheng Liao <liaohs@motorola.com>
Submit-Approved: Jira Key
This commit is contained in:
mahj8 2021-11-16 10:58:42 +08:00 • committed by Haijian Ma
commit f64b636d80

View file

@ -135,7 +135,7 @@
#define SGM4154x_TERMCHRG_CURRENT_STEP_uA 60000
#define SGM4154x_TERMCHRG_I_MIN_uA 60000
#define SGM4154x_TERMCHRG_I_MAX_uA 960000
#define SGM4154x_TERMCHRG_I_DEF_uA 180000
#define SGM4154x_TERMCHRG_I_DEF_uA 120000
/* charge current */
#define SGM4154x_ICHRG_CUR_MASK GENMASK(5, 0)