rsnd_get_slot_rdai() returns total slots (it returns 6 if total 6
channels) , and rsnd_get_slot_extend() returns extended SSI width
(it returns 8 if total 6 channels). This will be used on SSI multi
channel support too (It will return 2 if total 6 channels with 3 SSI).
But, it is using confusable naming.
This patch changes rsnd_get_slot_rdai() -> rsnd_get_slot(),
rsnd_get_slot_extend() -> rsnd_get_slot_width()
Signed-off-by: Kuninori Morimoto <[email protected]>
Signed-off-by: Mark Brown <[email protected]>