arm/dts: change the main charger icl 300ma

This platform don't have mmi_battery for 33W, we need change it to
battery power supply.
change max charger icl to 300ma when charger pump enable.

Change-Id: Ibbef411b53a47e305134d75217821c8d58e473df
Signed-off-by: mahj8 <mahj8@motorola.com>
Reviewed-on: https://gerrit.mot.com/2200417
SME-Granted: SME Approvals Granted
SLTApproved: Slta Waiver
Tested-by: Jira Key
Reviewed-by: Lei Chen <chenl18@motorola.com>
Reviewed-by: Huosheng Liao <liaohs@motorola.com>
Submit-Approved: Jira Key
This commit is contained in:
mahj8 2022-02-24 18:05:31 +08:00 • committed by panyq6
commit a506ab6e4b

View file

@ -392,8 +392,8 @@
<1000000>;
charger_device_0 {
chrg-name = "pmic-sw";
psy-name = "mmi_battery";
charging-curr-limited = <500000>;
psy-name = "battery";
charging-curr-limited = <300000>;
};
charger_device_1 {
chrg-name = "cp-master";