mirror of
https://github.com/BobTheBlinker/android_kernel_motorola_sm6375.git
synced 2026-10-24 21:54:34 -04:00
ARM: dts: msm: Update BCL, Alarm and CPU thermal mitigation for SHIMA
Update the BCL rule in SHIMA to include CDSP mitigation for all three violations. Update PM8350 alarm rule in SHIMA to have cpufreq as mitigation devcie instead of cpu-isolate cooling device for silver and gold cores. Update silver core mitigation to ensure minimum operating performance. Change-Id: I5ba29ee1e606cf9104e4ab4745606c473b9ea497
This commit is contained in:
parent
c44ace7d56
commit
ddaae4656a
2 changed files with 32 additions and 45 deletions
|
|
@ -49,6 +49,11 @@
|
|||
trip = <&b_bcl_lvl0>;
|
||||
cooling-device = <&msm_gpu 2 2>;
|
||||
};
|
||||
|
||||
vbat_cdsp0 {
|
||||
trip = <&b_bcl_lvl0>;
|
||||
cooling-device = <&cdsp_sw 2 2>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
|
|
@ -68,6 +73,11 @@
|
|||
trip = <&b_bcl_lvl1>;
|
||||
cooling-device = <&msm_gpu 4 4>;
|
||||
};
|
||||
|
||||
vbat_cdsp1 {
|
||||
trip = <&b_bcl_lvl1>;
|
||||
cooling-device = <&cdsp_sw 4 4>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
|
|
@ -78,6 +88,12 @@
|
|||
cooling-device = <&msm_gpu THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
|
||||
vbat_cdsp2 {
|
||||
trip = <&b_bcl_lvl2>;
|
||||
cooling-device = <&cdsp_sw THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
|
|
@ -98,6 +114,11 @@
|
|||
trip = <&c_bcl_lvl0>;
|
||||
cooling-device = <&msm_gpu 2 2>;
|
||||
};
|
||||
|
||||
vph_cdsp0 {
|
||||
trip = <&c_bcl_lvl0>;
|
||||
cooling-device = <&cdsp_sw 2 2>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
|
|
@ -118,6 +139,11 @@
|
|||
trip = <&c_bcl_lvl1>;
|
||||
cooling-device = <&msm_gpu 4 4>;
|
||||
};
|
||||
|
||||
vph_cdsp1 {
|
||||
trip = <&c_bcl_lvl1>;
|
||||
cooling-device = <&cdsp_sw 4 4>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
|
|
@ -129,6 +155,12 @@
|
|||
cooling-device = <&msm_gpu THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
|
||||
vph_cdsp2 {
|
||||
trip = <&c_bcl_lvl2>;
|
||||
cooling-device = <&cdsp_sw THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
|
|
@ -151,27 +183,6 @@
|
|||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
|
||||
pm8350_cpu0_freq {
|
||||
trip = <&pm8350_trip0>;
|
||||
cooling-device = <&CPU0 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
|
||||
pm8350_cpu1 {
|
||||
trip = <&pm8350_trip0>;
|
||||
cooling-device = <&cpu1_isolate 1 1>;
|
||||
};
|
||||
|
||||
pm8350_cpu2 {
|
||||
trip = <&pm8350_trip0>;
|
||||
cooling-device = <&cpu2_isolate 1 1>;
|
||||
};
|
||||
|
||||
pm8350_cpu3 {
|
||||
trip = <&pm8350_trip0>;
|
||||
cooling-device = <&cpu3_isolate 1 1>;
|
||||
};
|
||||
|
||||
pm8350_cpu4 {
|
||||
trip = <&pm8350_trip0>;
|
||||
cooling-device = <&cpu4_isolate 1 1>;
|
||||
|
|
|
|||
|
|
@ -834,12 +834,6 @@
|
|||
cooling-device = <&cpu0_isolate 1 1>;
|
||||
};
|
||||
|
||||
cpu00_cdev1 {
|
||||
trip = <&cpu00_config>;
|
||||
cooling-device = <&CPU0 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
|
||||
cpu00_cdev2 {
|
||||
trip = <&cpu00_config1>;
|
||||
cooling-device = <&cpu0_hotplug 1 1>;
|
||||
|
|
@ -872,12 +866,6 @@
|
|||
cooling-device = <&cpu1_isolate 1 1>;
|
||||
};
|
||||
|
||||
cpu01_cdev1 {
|
||||
trip = <&cpu01_config>;
|
||||
cooling-device = <&CPU0 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
|
||||
cpu01_cdev2 {
|
||||
trip = <&cpu01_config1>;
|
||||
cooling-device = <&cpu1_hotplug 1 1>;
|
||||
|
|
@ -910,12 +898,6 @@
|
|||
cooling-device = <&cpu2_isolate 1 1>;
|
||||
};
|
||||
|
||||
cpu02_cdev1 {
|
||||
trip = <&cpu02_config>;
|
||||
cooling-device = <&CPU0 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
|
||||
cpu02_cdev2 {
|
||||
trip = <&cpu02_config1>;
|
||||
cooling-device = <&cpu2_hotplug 1 1>;
|
||||
|
|
@ -948,12 +930,6 @@
|
|||
cooling-device = <&cpu3_isolate 1 1>;
|
||||
};
|
||||
|
||||
cpu03_cdev1 {
|
||||
trip = <&cpu03_config>;
|
||||
cooling-device = <&CPU0 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
|
||||
cpu03_cdev2 {
|
||||
trip = <&cpu03_config1>;
|
||||
cooling-device = <&cpu3_hotplug 1 1>;
|
||||
|
|
|
|||
Loading…
Reference in a new issue